Cable vulcanizing autoclave

Cable vulcanizing autoclave

The steam vulcanization tank adopts PLC computer fully automatic control of temperature, pressure, and vulcanization time. Steam enters from the bottom of the tank, and a steam inlet is installed at the bottom of the tank. The inlet is automatically controlled by a pneumatic angle seat valve.

Welcome to inquire by phone: 086+18053634353

Introduction to cable vulcanization tank:

The steam vulcanization tank adopts PLC computer fully automatic control of temperature, pressure, and vulcanization time. Steam enters from the bottom of the tank, and a steam inlet is installed at the bottom of the tank. The inlet is automatically controlled by a pneumatic angle seat valve. The steam diffusion tube is arranged at the bottom of the tank, and the steam small holes (divided into 4mm and 5mm) in the diffusion tube are densely arranged according to certain rules and inclined angles to ensure that the temperature of the steam enters the tank and spreads evenly to the surrounding areas, preventing uneven steam diffusion and uneven product heating caused by direct steam heating. The temperature inside the vulcanization tank is uniform without dead corners. After setting the work program, the control system automatically performs intake, exhaust, temperature rise, insulation, vulcanization and other work. After vulcanization is completed, it automatically shuts off and emits an audible and visual alarm sound prompt. The temperature and pressure inside the vulcanization tank are kept constant and uniform, which solves the problem of uneven product quality caused by uneven temperature and pressure inside the tank.


Vulcanization tank model parameters:

ltem

Parameter

Working diameter(mm)

600-5000

Working length(mm)

800-30000

Working pressure(MPa)

0.6-10

Operating Temperature(℃)

100-500

Temperature control accuracy(℃)

±0.5-±3.0

Uniformity inside the tank(℃)

1.0-3.0

Pressure control accuracy(MPa)

±0.01

Opening method

Manual, hydraulic

Heating method

Steam (requires external steam source)


Composition of vulcanization tank system:

1) Door opening system

a) According to user needs, manual door opening or hydraulic door opening can be selected.

b) The flange is forged and formed to meet the standard requirements.

c) Silicone rubber sealing ring (resistant to high temperature of 210 degrees), capable of withstanding the maximum working pressure and temperature of the vulcanization tank.

2) Heating method: steam

Steam enters from the bottom of the tank, and a steam inlet is installed at the bottom of the tank. The inlet is automatically controlled by a pneumatic angle seat valve. The steam diffusion tube is arranged at the bottom of the tank, and the steam small holes (divided into 4mm and 5mm) in the diffusion tube are densely arranged according to certain rules and inclined angles to ensure that the temperature of the steam enters the tank and spreads evenly to the surrounding areas, preventing uneven steam diffusion and uneven product heating caused by direct steam heating. The temperature inside the vulcanization tank is uniform without dead corners.

3) Safety Chain

a)、 Manual interlock: Only when the manual interlock valve is closed during operation, can the tank be stamped. Otherwise, the manual interlock valve is connected to the outside of the tank, and pressure cannot be formed inside the tank. When opening the door, the manual interlock must be turned on, otherwise the can door cannot be rotated or opened. Ensure that the tank door can only be opened in a pressure free state.

b)、 Pressure automatic safety interlock: A set of pressure automatic interlock device is installed at the top of the tank door. When the pressure inside the tank reaches 0.01mpa, the suspension interlock will automatically float up and lock the tank door. As long as there is pressure inside the tank, the tank door cannot be opened to prevent safety hazards caused by workers' misoperation.

4) Insulation method

50mm aluminum silicate insulation cotton is laid on the outer side of the cylinder, and 1.5mm cold-rolled plate is used for insulation protection, with anti-corrosion coating on the outside.

5) Sealing method

The tank door is equipped with a flange inflatable silicone sealing ring, which is automatically inflated and sealed by compressed air during operation. The air pressure inside the tank pushes the sealing ring out of the groove. As long as there is pressure inside the tank, the tank door will not leak out, and the higher the pressure, the better the sealing. When opening the door, release the air to release the pressure inside the sealing groove, and the sealing ring automatically returns to the flange sealing groove. The inflatable sealing design makes the sealing ring less prone to wear, convenient and versatile, easy to maintain, and the sealing effect is significantly better than other methods. The sealing ring has a long service life.